Profile Run tool feature definition setting ought to re-symbolize drainage objects in profiles

At present, when selecting a feature definition for a profile run, it only affects the construction element created immediately after defining the profile run. It would make sense to have a setting where the feature definition of the profile run o...
9 months ago in Drainage and Utilities 0 Future consideration

Drainage Annotation - Anchor to top of grate elevation

Currently, the only datum for drainage annotations is set for invert. Some municipalities require annotation to be placed at grate elevation.
12 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Add ability to set default Engineering Libraries for all users

As it stands, I can make a new Engineering Library on a network drive to share with other users, but if I wanted to make that library the "default", I can't without having to make the change for each individual user.
over 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Make Grips Visible and Useable on 4k displays

When using Grips for Structures and Pipes - the grip blends too much into the background color, and on a 4K screen is TINY. The pipe grip is annoying to select (it only appears when I select the centerline of the pipe) but when adjusting or swapin...
almost 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer / User Interface 1 Future consideration

Add report for information about pipe bends

Kindly add a non-graphical way of identifying whether a pipe contains bends or not and information about the coordinates. The report is required to produce pipe setting out schedules and share the coordinates with the contractor. It would be...
almost 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

limit the number of Rows in the Elevation-Area Table.

I get close to 40-50 rows of data when I assign a "pond" to a terrian. I only need data every 0.1ft but it is providing much more.
about 2 years ago in Drainage and Utilities 0 Future consideration

Visualization of Flood Fill based on min and max height values

A function of flood fill a portion of the terrain based on a min height and max height value. It allows a drainage engineer to visually check if a certain flood top water level will flow beyond the project boundary. Is there a way to do this in Op...
over 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Generate Report of Construction Pipe Lengths, Start-Stop Station, and Offsets based on Keymap

Would like to utilized Asset Manager or a similar tool to quickly obtain quantities for drainage structures, namely pipes, based on a keymap. The idea is to feed the tool a keymap file, a file containing shapes representing each sheet, the tool us...
over 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Allow for easier rotation of utility nodes in profile

Multiple options should be available (node handles that can be manipulated, a match slope to conduit option in properties, a degree value that can be keyed-in, etc). This should allow for simplified placement of cell nodes that serve as pipe fitti...
about 1 month ago in Drainage and Utilities 2 Future consideration

Ability to add bends in watermain and when the bend angle is changed to geometry updates

When laying out watermain pipes the bends can be 45 degrees, 22.5 degrees, etc. These bends are modeled as nodes in our workspace so we can report of them and display them in our drawings. If the angle of the pipe adjusts, we want the node feature...