Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Compound and Reverse Curve Annotation

There is no civil geometry property exposed for "Arc Begin Point Label" or "Arc End Point Label". This leads to a discrepancy in the way that points are labeled for PCC and PRC on the alignment when compared to the curve data table. These annotati...
5 days ago in Annotation / OpenRail Designer / OpenRoads Designer 0 Future consideration

Auto Annotate Conduits and Nodes

Have the auto annotate toggle (in the feature definition toolbar) work when placing nodes and conduits that have an annotation group linked through the feature symbologies.
18 days ago in Annotation / Drainage and Utilities 0 Planned

Import SignCAD Labels as Editable ORD Multi-line Text

Issue Currently, when SignCAD signs are imported into ORD, labels and dimension text do not import as standard editable ORD text. Instead, the text is brought in as individual characters. This makes simple annotation edits difficult and time-consu...
about 1 month ago in OpenRoads Designer 0 Future consideration

SuperelevationToCSV.xsl does not export non-linear curve lengths

The Superelevation Report (SuperelevationToCSV.xsl) produces superelevation control lines without parabolic curves at transitions because the stylesheet is not coded to export Non-Linear Curve Lengths. Additionally, it is NOT currently possible fo...
10 days ago in OpenRoads Designer / Reports / Superelevation 0 Future consideration

Consider LRFD 10th edition stability check Art 6.7.4.2.2

This is a newly introduced article, for checking girder stability during construction stages when the section is non-composite.
12 days ago in Analytics / OpenBridge Designer 0 Future consideration

Formatting of output coordinates when alignment is exported to MXGenIO

Currently, the formatting of the output coordinates when an alignment is exported to MXGenio, gives a predefined format in the form of scientific notation (denoted in D+ notation). This enhancement request is to include a formatting option which c...
5 days ago in Import/Export / OpenRoads Designer 0 Future consideration

Modify Civil Label Settings After Placement

I am looking for a tool to modify the label settings after a civil label has been placed. In SS10, we had plan view labeler which could choose your style, delineator, and leader before placing and then after it has been placed it there was an edit...
5 months ago in Annotation / OpenRail Designer / OpenRoads Designer 0 Future consideration

Ability to add lines and points to drainage cells (2D/3D)

Revised Justification for DU Cell Enhancements If Drainage and Utility (DU) cells could incorporate linear and point features, these elements could be utilized as break lines within graphical filters for terrain modeling. Additionally, such featur...
4 months ago in Drainage and Utilities / OpenRoads Designer 0 Future consideration

Load Template from Schedule Generator from ProjectWise

The application (ProConcrete standalone/ProConcrete within OBM/Rebar Modeler in OBM 2026) only allows selection of a schedule generator template from a local drive. When the user tries to create rebar schedules using Schedule Generator, clicking t...
12 days ago in OpenBridge Modeler / Workspace 0 Future consideration

Catchment Collection Reports

Certain Catchment properties can be stored as collections (composite time of concentration and rational C by Land Cover are 2 that come to mind). For individual catchments these collections can be opened and a report generated, however it is tedio...
9 days ago in Drainage and Utilities / OpenRoads Designer / Reports 1 Planned