Ability to print without needing to go through named boundaries

We were previously able to drop a border cell in any file to easily be able to print and now it is not

Volumetric Meshes created as Scalable Meshes

For large scale projects, earthwork volumetric meshes cause considerable deficits in navigation performance due to the high count of vertices and faces to be calculated with each navigational operation. Use of scalable meshes for these components ...
8 months ago in Modeling / OpenRail Designer / OpenRoads Designer 0 Future consideration

Include column and shaft controlling service loads (RCPIER/LEAP)

When designing drilled shafts, there is no option to display controlling shear and moment loads (bottom of column). This is needed for the geotechnical engineer on designing th drilled shaft. For column design, it is sometime useful to also show c...
8 months ago in OpenBridge Designer 0 Future consideration

Template (ITL): add parameters for component length, spacing and individual

It could be useful for different purposes to be able to create component meshes of defined length (construction, pre cast slab). I suggest to add at least 3 parameters to any component: length of the component: the question is then, where to measu...
8 months ago in Modeling / OpenRail Designer / OpenRoads Designer 0 Future consideration

Sorting and Grouping of Corridors and Linear Templates

Currently Corridors and Linear Templates are very poorly sorted in Explorer. These need to at least be sorted alphabetically to allow users to easily find the Corridor/Linear template they are looking for. Our major projects have dozens and dozens...
over 3 years ago in Modeling 0 Future consideration

Don't process corridor for change of disabled Point Control or Parametric Constraint

Not sure why it does this, but it doesnt make sense that the software processes when these are changed although they are disabled. To aid in productivity, especially for large corridors, the corridor should check if the Point Control / Parametric ...
over 3 years ago in Modeling / OpenRail Designer / OpenRoads Designer 2 Future consideration

Drop Leading Zero in Civil Reports and Text Favorites

When utilizing civil geometry to create a parcel and then creating a Legal Description report within the Civil Reports, the software add a leading zero to a bearing of less than 10 degrees. For example, "North 07 degrees 09 minutes 12 seconds West...
over 1 year ago in Annotation / Item Types / OpenRail Designer / OpenRoads Designer / OpenSite Designer / Reports 0 Future consideration

Being able to add/remove references that are stored inside cross sectional saved view

Rather than creating a new cross sectional named boundary, it would be convenient for the saved views to synchronize with 3D reference window and level display. There could even be a feature to toggle this feature on and off for a saved view.
almost 2 years ago in Drawing Production / OpenRail Designer / OpenRoads Designer 0 Future consideration

LEAP Concrete LFD LLDF

I believe that LEAP isn't accurately calculating the LLDF for LFD. It appears to currently compute the LLDF for moment and shear correctly, but it doesn't appear to calculate the LLDF for reactions at all. If it were calculating the LLDF for react...
almost 2 years ago in OpenBridge Designer 0 Future consideration

Rules between reference files

Indicate in the reference manager if Civil Rules exist between files. When attempting to create a snap rule to an element that is in a reference file display a warning message. Prevent circular reference errors created by snap rules between refere...
over 1 year ago in OpenBridge Designer / OpenRail Designer / OpenRoads Designer / OpenSite Designer / OpenTunnel Designer / User Interface 0 Future consideration