Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 1756 of 1756

Improve Complex Terrains - Do not process terrain until all terrains are added and ordered

When creating complex terrains each time a terrain is added the software processes the new terrain. This can take a long time if multiple terrains are added and reordered to a complex terrain. Please edit the software to process the terrain only w...
about 3 years ago in OpenRail Designer / OpenRoads Designer / OpenSite Designer / Terrain 0 Future consideration

ORD Drainage/Utilities - Make Item Types Attached through Feature Definitions visible outside ORD

Based on service now case CS0300323, item types attached to drainage/utility nodes through feature definitions are not visible in MicroStation or i.dgns. However, if the item types are attached manually to nodes they are visible outside the civil ...
over 1 year ago in Drainage and Utilities / Workspace 0 Future consideration

Notification/warning if alignment doesn't have active profile.

If an aligmment has a vertical profile, can we please ensure that it's active. The profile creation process is labourious in this software, and to find out that your profiles are empty at the end of this process as there weren't active isn't great...
about 3 years ago in Geometry / OpenRail Designer / OpenRoads Designer / OpenSite Designer 6 Future consideration

Expand range options of Horizontal Feature Constraints

Horizontal feature constraints are a huge benefit to streamlining corridor modeling and tying design intent to civil geometry. The range options (-, 0, +) are pretty limited and often trigger components to behave improperly. Adding more options to...
over 2 years ago in Modeling / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Ability to Analyze Elevations in Dynamic Cross Section

Users would like the ability to quickly place a point in the dynamic section view to pull elevation information. It would be nice to have that text remain in place as you move from section to section, similar to the cut/fill volumes between sectio...
over 2 years ago in Modeling / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Geometry manipulator handles on offsets do not overlap with manipulator text with zero offset

Currently when offsetting elements, different manipulator handles appear, however unless you go into the preferences and changes the arrow manipulator size, it is very difficult or impossible to select the trim/extend manipulator handle because it...
almost 2 years ago in Geometry / OpenRail Designer / OpenRoads Designer / OpenSite Designer / User Interface 0 Future consideration

Enhancement to Group/Join Multiple Nodes in a Structure Node to Match Existing Survey Data

There is currently not a way to join/group multiple nodes to a structure node to match existing survey data. This node join/group capability is needed to match XYZ surveyed invert points (from field collection) and be able to use the Extract from ...
about 2 years ago in Drainage and Utilities 0 Future consideration

Drainage module conduits and nodes data to be added to Cross section Frame

Road Cross section are able to display template, Design and existing terrain surface within the frame. But if theres drainage infrastructure there is no way of displaying that data within the frame it has to be done as a point annotation.
3 months ago in Drainage and Utilities / OpenRoads Designer 0 Needs review

Ability to annotate the difference of slope for vertical curve (parabola)

Currently we can not annotate the grade difference on the profile parabola, We can use the Item types to build a expression to calculate the grade difference and then use the civil labeler, but this workflow works only if the profile is not comple...
10 months ago in Annotation / OpenRail Designer / OpenRoads Designer 0 Future consideration

Ability to manage outer/inner pipe wall symbology separate from linear/profile symbology settings.

Need the ability to see wall symbology but not centerline. If the centerline symbology is set to construction class so are the inside/outside walls and they don't print. If the centerline is set to 255 the inside/outside walls do display in print ...
10 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer 0 Needs review